Benefits
Series Resistance Heating Cables, fluoropolymer-insulated
- Highly flexible
- Small bending radius
- High operation temperatures
- High chemical resistance
- Moisture proof
Constant wattage heating cables with resistance wire
Heat tape and heating cable
As a global provider of electrical heat tracing solutions, eltherm offers a wide range of heating tapes, heating cables and trace heaters for various industrial applications. In most cases these are actually for freeze prevention or temperature maintenance. Due to the different designs of the outer jackets, we can cover temperatures of up to 900 °C* with our heaters.
Which insulation covers which temperature range?
- FEP (Fluorinated Ethylene Propylene) up to 200 °C
- PFA / PTFE (Perfluoroalkoxy Alkane / Polytetrafluoroethylene) up to 260 °C
- E-glass (E-Gglass fibre) up to 450 °C
- Quartz glass (Quartz glass fibre) up to 900 °C*
*For high-temperature applications, let our application engineers advise you without obligation.
Products in the field of Heating Cables and Heating Tapes

ELKM-AG
This versatile heating cable is used for frost protection and temperature maintenance, even under highly corrosive…

ELKM-AG-L
This versatile, factory terminated, heating cable is used for frost protection and temperature maintenance, even under…

ELKM-AG-N
This versatile heating cable is used for frost protection and temperature maintenance, even under highly corrosive…

ELKM-AG-E
This versatile heating cable is used for frost protection and temperature maintenance, even under highly corrosive…

ELP/Si
The installation of this heating cable is highly cost-efficient with any kind of heat tracing application thanks to the…

ELKM-AE
Use on apparatus, vessels, pipes, valves, etc., in which low bending radii also allow compact tracing on small…

ELKM-AS
Use on apparatus, vessels, pipes, valves, etc., in which low bending radii also allow compact tracing on small…

ELKM-A
Use on apparatus, vessels, pipes, valves, etc., in which low bending radii also allow compact tracing on small…

EL-Rail
The eltherm EL-Rail is a flat cable, combining six Fluoropolymer insulated series heating conductors in a silicone…

ELP/FEP
These parallel heating cables offer tremendous flexibility in use, as they can easily be cut to the required length off…

ELP/PFA
Parallel trace heaters with resistance wire offer enormous flexibility, because they can be cut to length and provide…

ELP/Si-F
These heating cables are particularly suitable for maintaining temperatures of up to +150 °C. Its great flexibility down…

EL-Track
EL-Track: Parallel resistance trace heater with constant wattage (W/m) power output, fluoropolymer insulation and…

EL-Point
Switch Heater El-Point: Parallel resistance constant wattage (W/m) trace heater, fluoropolymer insulated and with…
How does a heat tape work?
The heat is generated by allowing an electric current to flow through a specifically adapted conductive material with high electrical resistance, which is then heated up. According to Ohm's law, the heat performance depends on the resistance level (as a function of the specific resistance of the material, its cross section and length) as well as the electrical current flow and thus on the voltage applied. The electrical current flow must not be so high that the melting temperature of the conductor material or the limit temperature of the insulating carrier is reached. For power output regulation purposes, several resistances can be connected in parallel or in series.
Constant wattage heating cable with parallel resistance wires, serial heating cable or heating tape?
Parallel heat cable

Parallel heat cable
Parallel constant wattage heating cables with resistance wire (for example ELP/Si) consist of 2 supply conductors embedded in a first insulation. Wrapped around with the heating conductor, which is surrounded by a second insulation. The corresponding protective braid and the outer jacket provides maximum safety. For example: Typical applications are food industry for heating various pipes, vessels or valves as freeze prevention or temperature maintenance. The required nominal power output is calculated on the basis of various specifications, such as supply voltage, minimum and maximum ambient temperature and maintain temperature. Feel free to contact us!

Serial resistance heating cable
Serial resistance heating cables can be cut to length (e.g. ELKM-AG-L). The design of this heat cable type is based on a stranded or spirally wrapped heat conductor which is covered by the insulation. On top of this this insulation is a protective braid (e.g. ELKM-AE). To ensure a higher mechanical protection, there are variants with an additional outer jacket available (e.g. ELKM AG-L).

Heating tapes
Heating tapes are mainly used for applications that require high flexibility and power output. The design is similar to the series resistance cable, with the difference that they are placed double inside an additional insulation and can therefore also provide more power output. Due to their design, heating tapes are more resistant and optimally protected while at the same time being particularly flexible. They are often used for electrical trace heating on tanks and vessels.
In general, each heating cable and heating tape is operated with appropriate measuring and control technology. As an alternative without temperature control, we can also offer various self-regulating heating cables. We will be happy to advise you in order to find the best solution for your application!
What (among other things) must be taken into account when assembling and installing heating cables and heating tapes?
- Remove any sharp irregularities (burrs etc.) from the surface to be heated and clean and degrease the surface.
- Installation of the heating circuit should be carried out with original eltherm accessories. The trace heaters should be attached to the surface by means of self adhesive aluminium tape (approx. one patch every 300 mm).
- Attach heater to pumps, valves and other components in a way that these components are still accessible for maintenance or exchange without major mechanical stress to the heater.
- The given max. operating temperature of the components to be heated as well as the maximum trace heater temperatures must not be exceeded.
Approvals









Visiting from the US or Canada
Engineering your Advantage
Your Processes in Expert Hands
We develop complete solutions for processes in production, storage, handling, and transport. Our engineers are committed to understanding your exact technical requirements. Their pride is to develop the best possible heat tracing solution.
eltherm designer 2.01
eltherm designer provides the tools to calculate, select and plan EHT systems and solutions for vessels and tanks. Selecting the appropriate eltherm trace heater, picking the associated accessories, and calculating key elements of EHT design have never been easier. This software is provided free-of-charge.
This software is provided free-of-charge.