Bus wire |
Copper |
---|---|
1st insulation |
Fluoropolymer |
Heating conductor |
Heating conductor alloy |
2nd insulation |
Fluoropolymer |
Protective braid |
Copper, nickel-plated |
Outer jacket |
Fluoropolymer |
Constant wattage trace heater with resistance wire a
These parallel trace heaters offer tremendous flexibility in use, as they can easily be cut to the required length off the roll, with the assurance of constant power output. There is no need for a connecting cable and input can be unilateral. It is quick and easy to assemble, this saves a lot of time, and reduces costs considerably as a result. Since output of up to 60 W٫m is possible for lengths laid to piping, ELP parallel trace heaters are particularly suitable for piping with high output requirements such as in industrial process technology
The particularly temperature-resistant outer shell in Fluoropolymer and the high level of chemical resistance of the Fluoropolymer ensure a long useful life.
Checklist
Connection & end termination set |
||
---|---|---|
EL-ECP1 |
Silicone termination cap, transparent; for ELP/PFA up to 200 °C |
09112P1 |
EL-ECP+ |
Silicone termination cap, red; for ELP/PFA up to 260 °C |
09112PP |
EL-ECP-Ex |
Silicone termination cap, red; for ELP/PFA up to 260 °C, Ex-marking |
0X81EP1 |
ELVB-ELPA-25 |
Power connection kit, cold assembly, gland M25, PC |
091A050 |
ELVB-ELPEx-25 |
Power connection kit, cold assembly, gland M25, PE, Ex e |
0X81PA2 |
ELVB-ELPEx-20 |
Power connection kit, cold assembly, gland M20, brass, Ex d e |
0X81PPD |
ELVB-SRV-ELP |
Splice kit, shrink fit |
0911118 |
Chemistry and Petrochemistry
Bullaing construction
Food Processing Industry
Paper industry
Benefits
Single end power input
Can be cut to length
Constant power output per meter
High chemical resistanice
UV-resitance
Trace Heater classification
1126 Ex 60079-30-1 IC Gb
120 Ex 60079-30-1CD6
System classificationi
II 2G Ex 60079-30-1 IIC 16.12 Gh
2D Ex 60079-30-1 С Тxx°С. Пъ
Certification
IECE EPS 12.0009 U
IECEX EPS 21.0062 X
EPS 12 ATEX 1438 บ
EPS 21 ATEX 1198 X
Technical Information |
|
---|---|
Maximum withstand temperature |
260 °C |
Nominal voltage |
230 VAC up to 277 VAC* |
Max. Current |
40 A |
Min. Bending radius |
25 mm |
Min. installation temperature |
– 60 °C |
Min. start up temperature |
– 60 °C |
Cross section bus wire |
2 x 1.5 mm²; (2 x 4.0 mm² on request) |

NOTE
> Heating circuit lengths ELP٫PFA on the following conditions:
16 A circuit breaker, 80% utilisation, start up temp. 10 deg * C
> Max. 1096 voltage drop
> Power connection to one (1) heater end
> Greater lengths are possible with higher rated circuit breakers please contact eltherm
> Cables shall neither intersect nor contact,
> Provide protection by means of circuit breaker RCO 30 mA,
> Please observe the standaris
IEC-62395-2, EN 60519-10, EN 62395-2
Heating circuit length |
|||
---|---|---|---|
Type |
Power |
Length @ start up temp. |
|
ELP/PFA 15 BOT |
15.0 |
184.0 |
|
ELP/PFA 30 BOT |
30.0 |
100.0 |
|
ELP/PFA 45 BOT |
45.0 |
66.0 |
|
ELP/PFA 60 BOT |
60.0 |
50.0 |
Ordering information |
||||||
---|---|---|---|---|---|---|
Type |
Nominal |
Maintain |
Dimmensions |
Contact spacing |
Weight (1,5mm²) |
Article - No. approx. [g/m] |
ELP/PFA 15 BOT |
200 °C |
8.6 x 6.7 |
1.0 |
1.0 |
120 |
B0332015 |